Klin Monbl Augenheilkd ; 241(4): 402-405, 2024 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-38653294

RESUMO

BACKGROUND/OBJECTIVES: Ocular surface squamous neoplasia (OSSN) are among the most frequent non-pigmented malignancies of the ocular surface. They have a wide range of histological characteristics - ranging from mild epithelial dysplasia to invasive carcinoma of the squamous cells of the cornea. They may be restricted to the conjunctiva or also involve the cornea. As there are no leading symptoms in the early stages, diagnosis may be very delayed in patients who do not receive regular ophthalmological treatment. The present case series describes clinical and histological data on OSSN and includes clinical and histological data on OSSN, including possible clinical presentations, important risk factors, special histological and cytological features and therapeutic options. METHODS: Retrospective case series of patients with histologically confirmed severe epithelial dysplasia of the conjunctiva and cornea consistent with OSSN who presented to the Department of Ophthalmology in Basel University Hospital. The analysis covered demographic data, symptoms, diagnostic testing (photo documentation, brush biopsy), treatment and cytological and/or histological material and findings. RESULTS: We report on five patients aged between 41 and 92 years at the time of diagnosis. The histological findings in all patients included severe epithelial dysplasia, but with a heterogenous clinical presentation. In all cases, the lesion started in the conjunctiva, but traversed the limbus and extended to the cornea. The primary treatment was always surgical removal. In one patient, this had to be repeated several times due to recurrent metaplasia and was complemented by subsequent mitomycin C therapy. The clinical outcome ranged between total restitution of the original state to inevitable enucleation. CONCLUSION: The clinical presentation of OSSN is highly heterogenous, so that the initial diagnosis is difficult. There are no official guidelines for treatment, so that the treatment of choice varied between clinics. Regular ophthalmological follow-ups are recommended, even after complete surgical excision. Possible relevant concomitant diseases and risk factors must be identified before therapy.


Assuntos
Neoplasias da Túnica Conjuntiva , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Adulto , Idoso de 80 Anos ou mais , Neoplasias da Túnica Conjuntiva/diagnóstico , Neoplasias da Túnica Conjuntiva/patologia , Neoplasias da Túnica Conjuntiva/terapia , Doenças da Córnea/diagnóstico , Doenças da Córnea/patologia , Doenças da Córnea/terapia , Epitélio Corneano/patologia , Estudos Retrospectivos , Neoplasias Oculares/diagnóstico , Neoplasias Oculares/terapia , Neoplasias Oculares/patologia , Neoplasias Oculares/cirurgia , Carcinoma de Células Escamosas/patologia , Carcinoma de Células Escamosas/diagnóstico , Carcinoma de Células Escamosas/terapia , Carcinoma de Células Escamosas/cirurgia , Resultado do Tratamento
4.
Ther Adv Ophthalmol ; 16: 25158414241232258, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38516169

RESUMO

Background: New developments in artificial intelligence, particularly with promising results in early detection and management of keratoconus, have favorably altered the natural history of the disease over the last few decades. Features of artificial intelligence in different machine such as anterior segment optical coherence tomography, and femtosecond laser technique have improved safety, precision, effectiveness, and predictability of treatment modalities of keratoconus (from contact lenses to keratoplasty techniques). These options ingrained in artificial intelligence are already underway and allow ophthalmologist to approach disease in the most non-invasive way. Objectives: This study comprehensively describes all of the treatment modalities of keratoconus considering machine learning strategies. Design: A multidimensional comprehensive systematic narrative review. Data sources and methods: A comprehensive search was done in the five main electronic databases (PubMed, Scopus, Web of Science, Embase, and Cochrane), without language and time or type of study restrictions. Afterward, eligible articles were selected by screening the titles and abstracts based on main mesh keywords. For potentially eligible articles, the full text was also reviewed. Results: Artificial intelligence demonstrates promise in keratoconus diagnosis and clinical management, spanning early detection (especially in subclinical cases), preoperative screening, postoperative ectasia prediction after keratorefractive surgery, and guiding surgical decisions. The majority of studies employed a solitary machine learning algorithm, whereas minor studies assessed multiple algorithms that evaluated the association of various keratoconus staging and management strategies. Last but not least, AI has proven effective in guiding the implantation of intracorneal ring segments in keratoconus corneas and predicting surgical outcomes. Conclusion: The efficient and widespread clinical translation of machine learning models in keratoconus management is a crucial goal of potential future approaches to better visual performance in keratoconus patients. Trial registration: The article has been registered through PROSPERO, an international database of prospectively registered systematic reviews, with the ID: CRD42022319338.


Keratoconus: from fundamentals to future Artificial intelligence has changed how we treat the eye disease keratoconus in recent years. This study examines the many keratoconus therapies available, including surgery and contact lens wear, and how artificial intelligence can improve the safety and accuracy of these procedures. We combed through numerous papers to locate this data. To achieve the best outcomes, several parameters and methods should be evaluated. According to the study, some elements from eye scans are more useful than others. The idea behind using artificial intelligence is to help patients see better and treat keratoconus more effectively.

6.
Cornea ; 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38437155

RESUMO

PURPOSE: The purpose of this study was to highlight characteristic clinical and microscopic findings and report the long-term follow-up of pediatric excimer laser-assisted penetrating keratoplasty (excimer-PKP) for congenital stromal corneal dystrophy (CSCD). METHODS: A 2-year-old Greek child presented with CSCD at our department. Clinical examination showed bilateral flake-like whitish corneal opacities affecting the entire corneal stroma up to the limbus. Genetic testing identified a mutation of the decorin gene (c.962delA). The variant was not present in the parents and represented a de novo mutation. The uncorrected visual acuity was 20/100 in both eyes. Excimer-PKP (8.0/8.1 mm) was performed on the right eye at the age of 2.5 years and on the left eye at the age of 3 years. Postoperatively, alternating occlusion treatment was performed. RESULTS: The light microscopic examination demonstrated a disorganized extracellular matrix of the corneal stroma characterized by a prominent irregular arrangement of stromal collagen lamellae with large interlamellar clefts containing ground substance, highlighted by periodic acid-Schiff- and Alcian blue-positive reaction detecting acid mucopolysaccharides. Electron microscopy showed disorganization and caliber variation of collagen lamellae and thin filaments within an electron-lucent ground substance. The postoperative course was unremarkable. Both grafts remained completely clear 14 years postoperatively. Corneal tomography showed moderate regular astigmatism with normal corneal thickness. The corrected distance visual acuity was 20/25 in both eyes. CONCLUSIONS: Excimer-PKP for CSCD might be associated with excellent long-term results and a good prognosis, particularly when the primary surgery is performed at a very young age. However, this requires close postoperative follow-up examinations by an experienced pediatric ophthalmologist to avoid severe amblyopia.

7.
Drug Des Devel Ther ; 18: 365-374, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38347957

RESUMO

Ranibizumab, is a humanized, monoclonal antibody fragment that binds and inactivates vascular endothelial growth factor-A (VEGF-A) and VEGF-B. One of the main indications for an intravitreal treatment with ranibizumab is age-related macular degeneration (AMD), which is a retinal disease with a high worldwide socioeconomic impact. Biosimilars constitute biological products that demonstrate similar pharmacodynamic and pharmacokinetic characteristics with a reference product, as well as comparable clinical efficacy, safety and immunogenicity. Since the approval of the first biosimilar Razumab, there has been a variety of new biosimilars available on the market. They offer the advantage of the same good clinical and safety results at a better price. All Ranibizumab biosimilars that have gained approval were tested in double masked Phase 3 clinical studies. The use of Ranibizumab biosimilars in neovascular AMD is well reported in the bibliography. Nevertheless, over the last few years, there is a tendency of using biosimilars in other retinal diseases like retinopathy of prematurity (ROP), diabetic macular edema (DME) or polypoidal choroidal vasculopathy (PCV). In conclusion, ranibizumab biosimilars offer a promising avenue for the management of retinal diseases, especially in countries with lower socioeconomic status, where there is lack of availability of innovator ranibizumab. However, further research is required to fully explore their efficacy, safety, and long-term outcomes in a plethora of retinal diseases.


Assuntos
Medicamentos Biossimilares , Retinopatia Diabética , Edema Macular , Degeneração Macular Exsudativa , Recém-Nascido , Humanos , Ranibizumab/uso terapêutico , Medicamentos Biossimilares/efeitos adversos , Fator A de Crescimento do Endotélio Vascular , Inibidores da Angiogênese/uso terapêutico , Retinopatia Diabética/tratamento farmacológico , Análise Custo-Benefício , Edema Macular/tratamento farmacológico , Acuidade Visual , Degeneração Macular Exsudativa/tratamento farmacológico , Anticorpos Monoclonais Humanizados/uso terapêutico , Injeções Intravítreas , Ensaios Clínicos Controlados Aleatórios como Assunto
8.
Int J Ophthalmol ; 17(2): 380-391, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38371260

RESUMO

This narrative review aimed to have an algorithmic approach to microphthalmos by a systematic search. The definition can be related to a number of special phenotypes. In the more challenging cases of complex microphthalmos, relative anterior microphthalmos, and nanophthalmos, the surgeon can approach these cases more safely if they have a deep understanding of the anatomical variations and ideal formulae for intraocular lens computation and knows how to avoid intra- and post-operative complications. In this article, we review the criteria by which we recognize and describe pre-, intra-, and post-operative considerations, as well as discuss the ideal intraocular lenses for microphthalmos, given the intricate varieties of small eye phenotypes.

9.
Drug Des Devel Ther ; 18: 97-108, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38264539

RESUMO

The cornea, as the outermost layer of the eye, plays a crucial role in vision by focusing light onto the retina. Various diseases and injuries can compromise its clarity, leading to impaired vision. This review aims to provide a thorough overview of the pharmacological properties, therapeutic potential and associated risks of Rho-associated protein kinase (ROCK) inhibitors in the management of corneal diseases. The article focuses on four key ROCK inhibitors: Y-27632, fasudil, ripasudil, and netarsudil, providing a comparative examination. Studies supporting the use of ROCK inhibitors highlight their efficacy across diverse corneal conditions. In Fuchs' endothelial corneal dystrophy, studies on the application of Y-27632, ripasudil, and netarsudil demonstrated noteworthy enhancements in corneal clarity, endothelial cell density, and visual acuity. In pseudophakic bullous keratopathy, the injection of Y-27632 together with cultured corneal endothelial cells into the anterior chamber lead to enhanced corneal endothelial cell density and improved visual acuity. Animal models simulating chemical injury to the cornea showed a reduction of neovascularization and epithelial defects after application of fasudil and in a case of iridocorneal endothelial syndrome netarsudil improved corneal edema. Addressing safety considerations, netarsudil and ripasudil, both clinically approved, exhibit adverse events such as conjunctival hyperemia, conjunctival hemorrhage, cornea verticillata, conjunctivitis, and blepharitis. Monitoring patients during treatment becomes crucial to balancing the potential therapeutic benefits with these associated risks. In conclusion, ROCK inhibitors, particularly netarsudil and ripasudil, offer promise in managing corneal diseases. The comparative analysis of their pharmacological properties and studies supporting their efficacy underscore their potential therapeutic significance. However, ongoing research is paramount to comprehensively understand their safety profiles and long-term outcomes in diverse corneal conditions, guiding their optimal application in clinical practice.


Assuntos
1-(5-Isoquinolinasulfonil)-2-Metilpiperazina , Amidas , Benzoatos , Doenças da Córnea , Isoquinolinas , Piridinas , Sulfonamidas , beta-Alanina , Quinases Associadas a rho , Animais , Humanos , 1-(5-Isoquinolinasulfonil)-2-Metilpiperazina/análogos & derivados , beta-Alanina/análogos & derivados , Células Endoteliais
10.
Adv Ther ; 41(1): 231-245, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37884810

RESUMO

INTRODUCTION: This study investigated patient satisfaction levels in five premium intraocular lenses (IOLs). A secondary aim was to determine whether patient satisfaction was associated with the cataract grade before lens surgery. METHODS: In this multicenter prospective comparative study, 164 patients from diverse backgrounds underwent cataract surgery and were assigned for identical bilateral implantation of multifocal IOLs. In addition to visual performance, quality of life was measured using the National Eye Institute Refractive Error Quality Of Life Instrument (NEI-RQL 42) scoring questionnaire. The Sirius Scheimpflug Analyzer was used to evaluate the posterior cornea and aberrations. Finally, the association of patient satisfaction reports with the Pentacam Cataract Grading Scale (PCGS) and Lens Opacities Classification System (LOCS III) was evaluated. RESULTS: A considerable subjective improvement was observed in uncorrected far, near (40 cm), and intermediate (60 cm) visual acuity in the five groups (P values < 0.001). A significant difference was observed in mesopic and photopic contrast sensitivity between Symfony, Trinova, and AT LISA at the spatial frequency of 12 cycles per degree, favoring Symfony (P < 0.001). PanOptix users had considerably lower mean coma values (P < 0.001), while AT LISA users had lower mean spherical aberrations (P = 0.009) compared to the other groups. No additional safety concerns relating to IOLs were recorded. Mean satisfaction had a high correlation with LOCS and Pentacam Nuclear Staging (PNS) in each lens group, e.g., correlation coefficient and P value for AT LISA were respectively r = 0.99, P < 0.001 and r = 0.97, P = 0.004. CONCLUSION: Despite discrepancies between groups of lenses, most patients who received multifocal IOLs reported satisfaction at more than 3 years after the initial operation. A growing number of patients with cataracts are seeking spectacle-free vision with presbyopia-correcting IOLs. Hence, the high satisfaction rate among patients with cataract could indicate the value of offering a wider range of available lenses.


Assuntos
Catarata , Lentes Intraoculares , Lentes Intraoculares Multifocais , Humanos , Catarata/complicações , Implante de Lente Intraocular , Satisfação do Paciente , Estudos Prospectivos , Desenho de Prótese , Qualidade de Vida
11.
Ophthalmic Res ; 66(1): 1362-1375, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37972571

RESUMO

INTRODUCTION: The aim of this study was to describe and evaluate double PreserFlo MicroShunt implantation as a modified micro-invasive glaucoma surgery technique and to retrospectively compare the outcomes in a cohort of glaucoma patients with single or double implantation. MATERIALS AND METHODS: A retrospective data analysis of 57 glaucoma patients who consecutively underwent PreserFlo implantation was performed. Medical records were examined for patients' demographics, glaucoma type, intraocular pressure (IOP), medication, complications, and re-interventions. Two groups with single (n = 29) or double (n = 28) implantation were formed, and the outcomes were compared. In cases of two-stage double implantation (n = 17), the courses of the initial and the second implantations were compared. RESULTS: Mean preoperative IOP was significantly higher in the double compared to the single implantation group (29.4 ± 10.0 mm Hg; 21.7 ± 8.2 mm Hg; p = 0.003). Postoperatively, IOP was significantly lower in the double implantation group at various time-points (day 1, week 1, months 3 and 6; all p < 0.021). In the subgroup with two-stage procedures, mean preoperative IOP was 24.5 ± 8.5 mm Hg and 29.8 ± 10.1 mm Hg, respectively (p = 0.128). While immediately postoperatively, mean IOP lowering was clinically significant and similar following both procedures, the longer sustainable effect was observed after the second procedure (month 12: 25.5 ± 7.5 mm Hg; 12.4 ± 4.8 mm Hg; p = 0.001). No serious complications were observed. DISCUSSION/CONCLUSION: Double PreserFlo implantation appears safe and efficient for lowering IOP in glaucoma patients. Our preliminary findings suggest that double is superior to single implantation in terms of IOP lowering and the need for additional topical medication. Patients with insufficient IOP lowering following single implantation may benefit from a second implantation. Further research is warranted to evaluate double implantation as a first-line, one-stage procedure.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma de Ângulo Aberto , Glaucoma , Humanos , Estudos Retrospectivos , Glaucoma de Ângulo Aberto/cirurgia , Glaucoma/cirurgia , Pressão Intraocular , Tonometria Ocular , Resultado do Tratamento
12.
Ophthalmol Ther ; 12(6): 3013-3023, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37656400

RESUMO

INTRODUCTION: To evaluate the impacts of phacoemulsification preoperative and intraoperative factors on postoperative subfoveal choroidal thickness (SFCT). METHODS: This prospective interventional study was conducted on patients undergoing uneventful phacoemulsification with posterior chamber intraocular lens (IOL) implantation at the private clinic Ophthalmica Eye Institute, in Thessaloniki, Greece. Forty-six eyes of 46 patients were included in the study. Operative time (OT), phacoemulsification time (PT), effective phacoemulsification time (EPT) and phacoemulsification power (PP) were recorded for each patient. All patients received dexamethasone and nepafenac drops for 4 weeks postoperatively. Choroidal thickness (CT) at five anatomical locations was measured preoperatively and at 1 week, 1 month and 3 months postoperatively. RESULTS: Subfoveal choroidal thickness significantly increased over baseline thickness at 1 week postoperatively, returned to preoperative levels at 1 month and increased again at 3 months. Changes at 1 week and 3 months postoperatively correlated to baseline choroidal thickness (p = 0.023 and p = 0.011, respectively). Spherical equivalent (SE) inversely correlated to SFCT throughout the entire follow-up period (baseline p = 0.044, 1-week p = 0.011, 1-month p = 0.013, 3-month p = 0.018). EPT was the most significant determinant of increased SFCT at all time points (1-week p = 0.011, 1-month p = 0.01, 3-month p = 0.015). PT and PP significantly correlated to the SFCT increase at 3 months postoperatively (p = 0.033 and p = 0.043, respectively). OT was not associated with a change in SFCT at any time point (p > 0.05). CONCLUSION: Phacoemulsification can alter choroidal thickness until at least 3 months after surgery. Preoperative and intraoperative factors, notably SE, baseline SFCT, PT, PP and especially EPT, can influence postoperative CT increase.

13.
Diagnostics (Basel) ; 13(16)2023 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-37627975

RESUMO

The remarkable recent advances in managing keratoconus, the most common corneal ectasia, encouraged researchers to conduct further studies on the disease. Despite the abundance of information about keratoconus, debates persist regarding the detection of mild cases. Early detection plays a crucial role in facilitating less invasive treatments. This review encompasses corneal data ranging from the basic sciences to the application of artificial intelligence in keratoconus patients. Diagnostic systems utilize automated decision trees, support vector machines, and various types of neural networks, incorporating input from various corneal imaging equipment. Although the integration of artificial intelligence techniques into corneal imaging devices may take time, their popularity in clinical practice is increasing. Most of the studies reviewed herein demonstrate a high discriminatory power between normal and keratoconus cases, with a relatively lower discriminatory power for subclinical keratoconus.

14.
J Cataract Refract Surg ; 49(8): 864-868, 2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-37276261

RESUMO

PURPOSE: To compare the changes in the anterior chamber depth (ACD) and in the refractive outcomes after combined phacovitrectomy with respect to the endotamponade (balanced salt solution, air, sulfur hexafluoride [SF 6 , gas]). SETTING: Department of Ophthalmology, University Hospital Ulm, Ulm, Germany. DESIGN: Retrospective, longitudinal case-control study. METHODS: 160 eyes of 160 patients were included in the study. 120 eyes underwent phacoemulsification with in-the-bag implantation combined with vitrectomy and were divided into 3 groups according to tamponade (balanced salt solution, air, gas). 40 control eyes with cataract surgery only were included. Further inclusion criteria were uneventful surgery, no postoperative complications and absence of corneal pathology. Endpoints were ACD as measured by swept-source optical coherence tomography-based biometry (IOLMaster 700) preoperatively, 1 to 2 days and 6 weeks postoperatively and refractive prediction error (PE) using the Barrett and Haigis formulas. RESULTS: Within the first 2 days after surgery the ACD was shallower in the eyes left with gas or air tamponade, when compared with balanced salt solution or cataract surgery alone ( P < .001). This effect diminished 6 weeks later, and all eyes reached comparable ACD ( P = .396). The refractive PE was slightly, but statistically significantly higher in the gas group when compared with cataract surgery alone ( P = .012 for Barrett, P = .006 for Haigis). CONCLUSIONS: The resulting ACD after combined phacovitrectomy was independent of the tamponade used, but a gas-tamponade was associated with a higher refractive PE.


Assuntos
Extração de Catarata , Catarata , Lentes Intraoculares , Facoemulsificação , Erros de Refração , Humanos , Acuidade Visual , Estudos de Casos e Controles , Estudos Retrospectivos , Lentes Intraoculares/efeitos adversos , Refração Ocular , Erros de Refração/etiologia , Extração de Catarata/efeitos adversos , Facoemulsificação/métodos , Catarata/complicações , Câmara Anterior , Tamponamento Interno , Biometria/métodos
15.
J Clin Med ; 12(11)2023 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-37297875

RESUMO

It has been observed that an intraocular pressure (IOP) altering intervention in one eye is followed by a consensual response in the untreated fellow eye. The underlying mechanisms remain unclear. Involvement of neuronal, cytokine, and hormonal regulation of aqueous humor dynamics, as well as improved treatment adherence or systemic absorption of topically administered medical compounds, have been suggested. Our aim was to investigate the short-term effects of unilateral micropulse transscleral laser therapy on IOP in the fellow eye. All medical records of glaucoma patients who underwent micropulse transscleral laser therapy in a tertiary referral center between May 2019 and February 2023 were collected and analyzed. We found a significant reduction in IOP in the treated eyes, indicating successful treatment. In the fellow eyes, despite not having changed any of the pharmacological IOP-reducing therapies, a significant reduction in IOP from 17.0 ± 5.1 mmHg to 13.5 ± 4.4 mmHg (p < 0.01) was observed. This reduction was, however, short-term and reached statistical significance on the first postoperative day only. Our findings support the concept of consensual inter-eye responses to unilateral IOP changes. Further research is warranted to elucidate the mechanisms underlying this phenomenon.

19.
Drug Des Devel Ther ; 17: 961-975, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37020801

RESUMO

Fluocinolone acetonide (FAc) intravitreal implant (Iluvien®) is a corticosteroid implant indicated for the treatment of diabetic macular oedema (DMO) in patients who have previously received conventional treatment without good response, non-infectious posterior uveitis, and as an off-label treatment of the macular oedema secondary to retinal vein occlusion. FAc is a non-biodegradable 0.19 mg intravitreal implant which is designed to release FAc over 3 years at a rate of approximately 0.2 mcg per day. The aim of this review is to describe the special pharmacological properties of Iluvien and display the outcomes of the most important clinical trials and real-world studies regarding its efficacy and safety for the management of the above retinal disorders.


Assuntos
Retinopatia Diabética , Fluocinolona Acetonida , Edema Macular , Doenças Retinianas , Humanos , Retinopatia Diabética/tratamento farmacológico , Implantes de Medicamento/uso terapêutico , Fluocinolona Acetonida/administração & dosagem , Fluocinolona Acetonida/farmacologia , Fluocinolona Acetonida/uso terapêutico , Glucocorticoides/uso terapêutico , Injeções Intravítreas , Edema Macular/tratamento farmacológico , Doenças Retinianas/tratamento farmacológico , Anti-Inflamatórios/farmacologia , Anti-Inflamatórios/uso terapêutico
SELEÇÃO DE REFERÊNCIAS